Biosensors International Group Ltd
Home
Biosensors International Group Ltd
About Biosensors International

The Biosensors International group of companies develop, manufacture and market innovative medical devices for interventional cardiology and critical care procedures. Our aim is to improve patients’ lives through pioneering medical technology that pushes forward the boundaries of innovation.
Products & Technology
The Interventional Cardiology and Critical Care Products divisions both have track records of innovation in the development of next-generation medical technologies that make a difference in patients’ lives. A worldwide sales and marketing team and a network of distributors deliver our products to where they can help most.
- Interventional Cardiology
The Interventional Cardiology division is focused on the development, manufacture and commercialization of drug-eluting stents, bare metal stents and angioplasty catheters.
Drug-Eluting Stents (DES)
BioMatrix™ is Biosensors’ unique abluminal biodegradable polymer DES. Its abluminal coating is absorbed after 6 to 9 months (Data on file molecular weight <10kDa). It combines the proven safety of a DES with an abluminal biodegradable polymer, the proven efficacy of BA9™ and an advanced stent design.
Not available for sale in the United States and certain other countries
Bare Metal Stents
The latest generation bare metal stent, Gazelle™ (commercialized under the name S-Stent™ in Japan), has been developed using the proprietary Quadrature Link™ design for enhanced flexibility. Available in a broad range of sizes, the proven stent platform provides the deliverability necessary for easy positioning.
Not available for sale in the United States and certain other countries
Balloon Dilatation Catheters
Powerline™ offers excellent trackability and crossability for the treatment of complex lesions. The unique automated MultiPleat™ folding technology provides consistently low primary and secondary profiles to facilitate treatment of multi-vessel disease.
Not available for sale in the United States and certain other countries.
Critical Care Products
The Critical Care Products division develops and manufactures vascular catheters, pressure monitoring kits, arterial blood sampling kits and blood pressure transducers for use in open heart surgery and critical care areas of the hospital.
The cited trademarks are the property of Biosensors International Group, Ltd
Contact Details
Rue de Lausanne 29Morges
1110
Switzerland
Tel:
+ 41 21 804 80 00
Fax: + 41 21 804 80 02
contact: customerservice.EU@biosensors.com
website: www.biosensors.com
Fax: + 41 21 804 80 02
contact: customerservice.EU@biosensors.com
website: www.biosensors.com
Interventional Cardiology
Interventional Cardiology
At Biosensors, we strive to make an impact in patients’ lives by continually investing in and developing pioneering medical technology. Being at the forefront of new and innovative solutions helps us respond to the changing needs of the interventional cardiology market. We are the first company to offer a commercially available abluminal drug-eluting stent with a biodegradable limus technology on our proven stent platform, the S-Stent™.History of Firsts
We have demonstrated and proven our commitment to innovation in interventional cardiology as we were the:- First cardiology device company to develop a proprietary drug specifically designed for coronary stent use — Biolimus A9™ (BA9™); the compound is proprietary to Biosensors and is not licensed from a pharmaceutical company
- First company to successfully develop and launch an abluminal biodegradable polymer DES with a coating absorbed after 6 to 9 months (Data on file molecular weight <10kDa).
- First company to sponsor a randomized head-to-head comparison against a sirolimus eluting stent in an all-comers setting.
- First company to prove non-inferiority on a clinical endpoint against CYPHER® SELECT™ (trademark of Cordis Corporation)
Our interventional cardiology products are designed
to optimize your patient outcomes
to optimize your patient outcomes
BioMatrix™
Our new generation drug-eluting stent was created using the most advanced medical technology in its field. It offers patients many benefits by combining:
- Proven safety of a DES with
- An abluminal coating that reduces systemic drug exposure, provides more targeted drug release and promotes an endothelial coverage similar to a bare metal stent (BMS)
- A biodegradable polymer that is absorbed after 6 to 9 months (Data on file molecular weight <10kDa).
- Proven efficacy of our drug, BA9™, that has 10 times more lipophilicity than sirolimus, resulting in a more targeted release to the vessel wall
- Proven flexibility with advance stent design
Gazelle™
Based on the advanced design technology behind our proprietary S-Stent™ platform, Gazelle™ (commercialized under the name S-Stent™ in Japan) is our bare metal stent (BMS) that provides cardiologists with:- Flexible stent design with the Quatrature Link™ technology for excellent deliverability
Powerline™
Biosensors’ balloon dilatation catheter achieves the right balance of push-track-cross to meet clinical needs- The MultiPleat™ folding technology provides excellent cross and re-cross properties to facilitate use in complex procedures.
BioMatrix™
Drug-eluting stent - BioMatrix™
Abluminal Coating absorbed after 6-9 months *
Proven Safety of a DES with an Abluminal Biodegradable Polymer
Proven Efficacy of a Biolimus A9 ™ Drug
Proven Flexibility with Advanced Stent Design

Drug-eluting stent - BioMatrixTM
Biomatrix™ - The Abluminal Biodegradable Polymer DES

BioMatrix™ is Biosensors' unique abluminal biodegradable polymer DES. Its abluminal coating is absorbed after 6 to 9 months *. It combines the proven safety of a DES with an abluminal biodegradable polymer, the proven efficacy of BA9™ and an advanced stent design.
Not available for sale in the United States and certain other countries.
For more information on the abluminal biodegradable polymer, please click here. Alternatively, please click here to return tothe top of this page
Abluminal Coating absorbed after 6-9 months*
Abluminal Coating
No drug carrier or drug inside the stent allowing for:- More targeted drug release
- Reduced systemic exposure
- Early BMS-like endothelial coverage1
For more information on abluminal coating absorption, please click here. Alternatively, please click here to return tothe top of this page
Proven Safety of a DES with an Abluminal Biodegradable Polymer
Biodegradable Polymer
Confirmed Safety- with a 12.3% reduction in MACE compared to the Sirolimus eluting stent at 12months in LEADERS2
- with no late or very late stent thrombosis in STEALTH I3 out to 4years
Superior strut coverage at follow up
10 times better strut coverage4 of an abluminal biodegradable polymer BES than a durable symmetric polymer SES
- Abluminal biodegradable polymer BES achieves 96.4% of near to complete strutcoverage
More than 20 times better stent apposition4 of an abluminal biodegradable polymer BES than a durable symmetric polymer SES
Biolimus A9™ eluting stent with abluminal biodegradable polymer demonstrates preserved vasomotion5
- A high pacing stimulation induced abnormal vasomotion (vasoconstruction) of theSirolimus eluting stented vessel when normal vasomotion (vasodilation) was observedin the Biolimus A9™ eluting stented vessel
For more information on proven safety of a an abluminal biodegradable polymer safety, please click here. Alternatively, please click here to return to the top of this page
Proven Efficacy of a Biolimus A9™Drug
Biolimus A9™ (BA9™)
Low late loss- Lower level of late loss achieved in the LEADERS trial with the BiolimusA9™ eluting stent at 9 months compared to Sirolimus elutingstent6
- In Stent late loss in LEADERS = 0.13mm6
Highest lipophilicity of the common limus drugs8
- Minimizes systematic exposure and reduces the circulating drug into the bloodstream
- Due to high lipophilicity, the drug is rapidly absorbed by tissue
For more information on the proven efficacy of the BiolimusA9™ Drug, please click here. Alternatively, please click here to return to the top of this page
Proven Flexibility with Advanced Stent Design
S-Stent Platform
High Flexibility without compromising vessel supportQuadrature link™ design increases stent flexibility while preserving stent security and vessel scalfolding
Low Recoil9 and high radial strength9 for enhanced vessel support
Unmatched side branch access9
- Largest cell opening compared to current market leading DES
- * Data on file - molecular weight <10kDa
- Virmani R., Are resorbable coatings better?, oral presentation, PCR 2008
- Serruys P.W., LEADERS: Taking the LEAD in DES Clinical Excellence - 12 months results, oral presentation, TCT 2008. Data applicable to the stent used in the LEADERS trial
- Grube E., Safety and Performance Evaluation of Biosensors Biolimus A9™ Eluting Stent (BioMatrix™) STEALTH I: a 4-year safety follow-up, e-poster, TCT 2008
- Di Mario C., OCT: Differences between biodegradable and durable polymers - Insights from the LEADERS trial, oral presentation, TCT 2008. Data applicable to the stent used in the LEADERS trial
- Hamilos M. et al. on behalf of the Nobori Core investigators, Differential Effects of Drug-Eluting Stents on Local Endothelium-Dependent Coronary Vasomotion, J Am Coll Cardiol 2008 51:2123-2129. Data applicable to the stent used in the Nobori Core trial
- Windecker S. et al., Biolimus-eluting stent with biodegradable polymer versus Sirolimus-eluting stent with durable polymer for coronary revascularization (LEADERS): a randomised non inferiority trial; The Lancet 2008; 372 No. 9644: 1163-1173. Data applicable to the stent used in the LEADERS trial
- Windecker S. et al., NEJM 2005; Morice M.-C. et al., JAMA 2006; Serruys P.W. et al., EuroIntervention 2006; Stone G.W. et al., JAMA 2008; Costa M. et al., Am J Card 2006; Chevalier B. et al., EuroIntervention 2006; Ostojic M. et al., EuroIntervention 2008; Stone G.W. et al., NEJM 2004; Krukoff M.W., JACC 2008; Verheye S. et al., ACC/SCAI 2008
- Data on file
- Schmidt W. et al., A comparison of the mechanical performance characteristics of seven drug-eluting stent systems; CCI 2009 73: 350-360
- The graph only represents DES that are commercially available
Gazelle™
GAZELLE™ - Rapid Exchange Coronary Stent SystemTM
High Flexibility without compromising Vessel Support
- Flexible stent design with the Quatrature Link™ technology for excellent deliverability
- Enhanced vessel support with minimal recoil (3.67%)1
Not available for sale in the United States and certain other countries.
- Schmidt W. et al., A comparison of the mechanical performance characteristics of seven drug-eluting stent systems; CCI 2009 73: 350-360. Internal bench testing was performed on the mechanical characteristics of the Gazelle coronary stent system to support data published on the mechanical characteristics of the BioMatrix™ DES in the report. The internal bench testing concluded that the mechanical characteristics of the Gazelle stent are not impacted by the addition of the drug/polymer coating
Powerline™
Balloon Dilatation Catheters: Powerline™
Take the Fast Track to Superior Patient Outcomes
The advanced catheter technology of Powerline™ is designed to offer the right balance of PUSH, TRACK and CROSS to ensure optimal balloon placement and expansion:
A. PUSH
The PTFE-coated hypotube in combination with the power stylet transition in the middle shaft provides the right balance between pushability and trackability offering a smoother force transmission from the proximal to distal portion of the catheter shaft.B. TRACK
The combination of the Slip-X™ hydrophilic coating and the flexible distal shaft ensure excellent trackability and crossability for complex lesions or tortuous anatomy.C. CROSS
The flexible low profile tip section with smooth transition and short bonding offers a gradual increase towards the balloon to facilitate lesion entry. The advanced MultiPleat™ folding technology of Powerline™ is designed to offer exceptional lesion crossability and uniform balloon expansion as well as excellent balloon re-wrap and re-cross properties for treating challenging lesions.MultiPleat™ Folding Technology
The MultiPleat™ folding technology is designed to facilitate the treatment of multiple lesions as the machine folding provides a more consistent rewrap of the balloon. This fully automated mechanism offers exceptional lesion crossability and uniform balloon expansion, as well as improved re-cross properties that may facilitate complex procedures and reduce procedural time.Not available for sale in the United States and certain other countries.
Critical Care
Critical Care TechnologyTM
Biosensors International’s Critical Care Products division fosters the development of critical care catheter systems, hemodynamic monitoring, and related devices used during heart surgery procedures and intensive care treatment
![]() | ACCUTRANS™ Disposable Blood Pressure TransducerACCUTRANS™ is a fully disposable blood pressure transducer system that delivers vital accuracy in invasive blood pressure measurement with lowest possibility of zero drift.Its unique, Fast-Flush Device provides a means of intermittent and rapid manual flushing of the system. The Fast-Flush Device also prevents clotting and backflow of blood through the catheter. The ACCUTRANS Fully Disposable Blood Pressure Transducer System is available in standard-kits and custom-kit configurations for neonatal, pediatrics, umbilical and intracranial invasive blood pressure monitoring. Customized Kits It is possible to configure custom kits to meet your procedural needs. You may ask for any existing component to be configured with other commercially available components. The customized kits help you to increase efficiency in the set-up process and ensure accuracy in components selection. It eliminates wastage and helps you to save time and cost. ACCUTRANS™ Brochure (PDF) |
![]() | |
![]() | BIOTRANS™BIOTRANS™ transducer is the first and only blood pressure transducer that combines the performance, quality and ease of use of a fully disposable blood pressure transducer with the cost savings of a re-usable system.It also incorporates a number of intelligent and exclusive features for saving caregivers’ valuable time.Features and Benefits
It is possible to configure custom kits to meet your procedural needs. You may ask for any existing component to be configured with other commercially available components. The customized kits help you to increase efficiency in the set-up process and ensure accuracy in components selection. It eliminates waste and helps you to save time and cost. BIOTRANS™ Brochure (PDF) |
![]() | |
![]() | Multi-Lumen Central Venous CatheterBiosensors International offers a wide range of Central Venous Catheters (CVC) for patients, from infants to adults, to administer medication or fluids, obtain blood tests and directly obtain cardiovascular measurements such as the central venous pressure.Our CVCs are made with a special polyurethane material which softens upon insertion into the body. This creates less trauma for the patient and provides greater control to the doctor during catheter insertion. The soft-tip at the distal end allows the catheter to be navigated easily within the vessel without irritating the vessel walls. Our CVCs can be used with the commonly-available straight introducer needle, as well as the Y-Valve needle which allows for easy guide-wire insertion while minimizing air embolism and backflow of blood. Features and Benefits
It is possible to configure custom kits to meet your procedural needs. You may ask for any existing component to be configured with other commercially available components. The customized kits help you to increase efficiency in the set-up process and ensure accuracy in components selection. It eliminates waste and helps you to save time and cost. Multi-Lumen Central Venous Catheters (PDF) |
![]() | |
![]() | Thermodilution and Pulmonary Artery CathetersBiosensors International offers two types of catheters for pulmonary artery monitoring: Thermodilution (TD) Catheters and Pulmonary Artery (PA) Catheters. TD Catheters include a thermistor in its final assembly, which helps provide Cardiac output measurements.Catheter tips often migrate to small arterial branches that are unable to safely accommodate inflated balloons. The SafetyWedge™ device has been introduced to reduce the risk of pulmonary artery rupture due to balloon over-pressurization. The most serious complication associated with PA catheter monitoring. The SafetyWedge™ device acts as a pressure relief valve to prevent over-pressurization of the distal balloon. This not only averts vessel rupture but the balloon rupture as well, and alerts the clinician to reposition the catheter. |
![]() | |
![]() | BIOTRAY™The BIOTRAY™ device offers the benefits of the SafetyWedge™ Thermodilution/pulmonary artery catheter and the Introducer Kit, all in a convenient, fully-accessorized all-in-one tray.Features and Benefits
|
![]() | |
![]() | Bipolar Pacing CatheterBiosensors’ Bipolar Pacing Catheter for temporary transvenous cardiac pacing was developed in response to market demand for a safe, secure and accurate device to support critical procedures in the catherization Lab, CCU, and Emergency Room settings.Features and Benefits
|
![]() | |
![]() | Embolectomy CatheterBiosensors’ Embolectomy Catheters offer a flexible PVC body coupled with a strong and symmetrical balloon. Its soft-tip material allows for easy arterial insertion. They come in a variety of sizes to cater to a wide range of patients from different age groups.Features and Benefits
|
![]() | |
Press Releases
Press Releases
| May 20, 2009 | New Insights into LEADERS trial |
| Mar 6, 2009 | BioMatrix 2.25mm launch |
| Oct 15, 2008 | LEADERS 12 month follow up and OCT subset analysis |
| Sept 1, 2008 | LEADERS 9 month data presentation |
| Mar 14, 2008 | Launch of e-BioMatrix 5000 patient registry |